Simultaneous spectrophotometric determination of cobalt,copper and nickel using 1-(2-thiazolylazo)-2-naphthol by chemometrics methods

Ali Niazi Ateesa Yazdanipour

引用本文: Ali Niazi,  Ateesa Yazdanipour. Simultaneous spectrophotometric determination of cobalt,copper and nickel using 1-(2-thiazolylazo)-2-naphthol by chemometrics methods[J]. Chinese Chemical Letters, 2008, 19(7): 860-864. doi: 10.1016/j.cclet.2008.04.047 shu
Citation:  Ali Niazi,  Ateesa Yazdanipour. Simultaneous spectrophotometric determination of cobalt,copper and nickel using 1-(2-thiazolylazo)-2-naphthol by chemometrics methods[J]. Chinese Chemical Letters, 2008, 19(7): 860-864. doi: 10.1016/j.cclet.2008.04.047 shu

Simultaneous spectrophotometric determination of cobalt,copper and nickel using 1-(2-thiazolylazo)-2-naphthol by chemometrics methods

  • 基金项目:

    The authors gratefully acknowledge the support to this work from Islamic Azad University of Arak Research Council.

摘要: The simultaneous determination of cobalt,copper and nickel using 1-(2-thiazolylazo)-2-naphthol (first figure of this article) by spectrophotometric method is a difficult problem in analytical chemistry,due to spectral interferences.By multivariate calibration methods,such as partial least squares (PLS) regression,it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range.Orthogonal signal correction (OSC) is a preprocessing technique used for removing the information unrelated to the target variables based on constrained principal component analysis.OSC is a suitable preprocessing method for PLS calibration of mixtures without loss of prediction capacity using spectrophotometric method.In this study,the calibration model is based on absorption spectra in the 550-750-nm range for 21 different mixtures of cobalt,copper and nickel.Calibration matrices were formed from samples containing 0.05-1.05,0.05-1.30 and 0.05-0.80 μg mL-1 for cobalt,copper and nickel,respectively.The root mean square error of prediction (RMSEP) for cobalt,copper and nickel with OSC and without OSC were 0.007,0.008,0.011 and 0.031,0.037,0.032 μg mL-1,respectively.This procedure allows the simultaneous determination of cobalt,copper and nickel in synthetic and real samples and good reliability of the determination was proved.

English

  • 加载中
计量
  • PDF下载量:  0
  • 文章访问数:  1039
  • HTML全文浏览量:  37
文章相关
  • 收稿日期:  2008-03-09
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

/

返回文章