2-巯基苯并咪唑保护的铜纳米团簇的制备及银离子检测

蔡志锋 ,  陈思颖 ,  庞姝琳 ,  宋爽 ,  贾康 ,  毛钰瑾 ,  田芳 ,  张彩凤

引用本文: 蔡志锋, 陈思颖, 庞姝琳, 宋爽, 贾康, 毛钰瑾, 田芳, 张彩凤. 2-巯基苯并咪唑保护的铜纳米团簇的制备及银离子检测[J]. 应用化学, 2020, 37(5): 587-594. doi: 10.11944/j.issn.1000-0518.2020.05.190312 shu
Citation:  CAI Zhifeng, CHEN Siying, PANG Shulin, SONG Shuang, JIA Kang, MAO Yujin, TIAN Fang, ZHANG Caifeng. Synthesis of 2-Mercaptobenzimidazole-Functionalized Water-Soluble Copper Nanoclusters and Their Application to the Determination of Ag+[J]. Chinese Journal of Applied Chemistry, 2020, 37(5): 587-594. doi: 10.11944/j.issn.1000-0518.2020.05.190312 shu

2-巯基苯并咪唑保护的铜纳米团簇的制备及银离子检测

    通讯作者: 田芳, 副教授; Tel:0351-2506530;E-mail:tianfqq@sina.com; 研究方向:重金属修复; 张彩凤, 教授; Tel:0351-2506530;E-mail:zhangcf301@yahoo.com.cn; 研究方向:腐植酸的结构及应用
  • 基金项目:

    山西省应用基础研究基金面上自然基金项目(201801D121257)资助

摘要: 以2-巯基苯并咪唑为保护剂,聚乙烯吡咯烷酮为稳定剂,水合肼为还原剂,“一锅法”合成2-巯基苯并咪唑保护的,高稳定性、强荧光、大斯托克斯位移的铜纳米团簇(Cu NCs),并用于检测水样中的银离子含量。采用透射电子显微镜(TEM)和X射线光电子能谱(XPS)对铜纳米团簇的结构进行表征,通过荧光光谱和紫外可见光谱对其光学性能进行研究。研究表明:该铜纳米团簇的最大激发和发射波长分别为340和558 nm,在日光灯和紫外灯下分别为无色和橙色。Cu NCs具有较高的分散性,尺寸大小为2~3 nm。在最佳反应条件下,铜纳米团簇可以选择性地被银离子猝灭,且灵敏度高,线性范围为1~40 μmol/L,检测限为0.5 μmol/L。该方法用于检测实际水样(自来水、湖水)中银离子的浓度,结果令人满意,表明在环境监测中有非常高的应用价值。

English

  • 随着社会和工业的发展,大量的重金属离子被排放到环境中,其对环境和人体的健康均构成严重威胁[1]。作为贵金属,银已广泛应用于电子行业以及摄影和成像行业,然而银离子(Ag+)却被归为重金属污染物毒性最高的类别。尽管不是生物蓄积性毒素,但Ag+可以使巯基酶失活,能够与各种代谢产物的胺基、咪唑和羧基结合,并可以置换骨骼中羟基磷灰石中的必需金属离子,例如Ca2+和Zn2+[2]。因此,准确监测环境中Ag+的含量对保护环境和人体免受Ag+的毒害是至关重要的,开发灵敏度高和选择性好的测定方法具有重要意义[3-4]。目前,已经有一系列的检测方法用于测定环境中的Ag+,例如:电热原子吸收光谱法(ETAAS)[5-6]、伏安法[7]、电感耦合等离子体原子发射光谱法(ICP-AES)[8]、电感耦合等离子体质谱(ICP-MS)[9]和电位测定法[10]等。尽管这些方法具有很高的选择性和灵敏度,但它们有些复杂、昂贵且耗时较长。因荧光传感器具有操作简单、灵敏度高、响应直观快速而逐渐受到关注[11-13]。到目前为止,荧光探针主要有有机染料分子[14]、半导体量子点[15]和金属纳米粒子[16]等,尽管有机染料分子和半导体量子点具有很好的选择性,但是其很容易造成二次污染,且制备温度较高、反应时间较长。

    近年来,金属纳米团簇已成为生命科学等领域的研究热点。金属纳米团簇具有尺寸小、光稳定性好、生物相容性好、斯托克斯位移大、无毒等优点,已在环境检测、医疗卫生、生物传感器、细胞标记及成像和生物探针等领域得到广泛应用[17-19]。研究比较多的是金、银、铜纳米团簇,合成方法主要有刻蚀合成法、相转移合成法、电化学法、光还原法、声化学合成法和微波辅助法等[20-22]。保护剂主要有蛋白质、硫醇、DNA等[23-25]。目前,用于检测Ag+的金属纳米团簇主要是贵金属金和银纳米团簇[16, 26],铜纳米团簇研究比较少。

    本文以2-巯基苯并咪唑为保护剂,聚乙烯吡咯烷酮为稳定剂,水合肼为还原剂,通过化学还原法合成2-巯基苯并咪唑稳定的铜纳米团簇。采用透射电子显微镜(TEM)、X射线光电子能谱分析(XPS)、紫外可见光谱(UV-Vis)和荧光光谱(FL)等进行表征。并建立高选择性和高灵敏度的测定银离子的新方法,用于实际水样中银离子的测定。

    FEI Tecnai G2 F20型透射电子显微镜(美国FEI公司);ESCALAB 250XI型X射线光电子能谱分析(美国ThermoFisher Scientific公司);8453型紫外可见光谱仪(美国安捷伦公司);F-7000型荧光光谱仪(日本日立公司)。

    硝酸铜、2-巯基苯并咪唑、聚乙烯吡咯烷酮、水合肼(分析纯,上海阿拉丁生化科技股份有限公司);氢氧化钠、盐酸(分析纯,天津市富宇有限公司)。实验用水为超纯水。

    分别将2-巯基苯并咪唑溶液(4 mL, 1 mmol/L)、聚乙烯吡咯烷酮溶液(4 mL, 0.1 mmol/L)、水合肼溶液(2 mL, 100 mmol/L)和硝酸铜溶液(1 mL, 10 mmol/L)加至50 mL烧杯中,混合溶液加水稀释至25 mL,室温下搅拌15 min,溶液逐渐由无色变为淡黄色,表明成功得到铜纳米团簇。最后,在超纯水中使用截留相对分子质量为3000透析袋透析溶液48 h以除去未反应的底物。获得的溶液在4 ℃下储存用于进一步检测实验。

    将一系列不同浓度的Ag+溶液添加到1 mL Cu NCs和500 μL的缓冲溶液的混合溶液中(Ag+的最终浓度为0、1、2、5、7、10、15、20、25、30、40、50、60、70、80、90和100 μmol/L)。混合物在室温下孵育5 min后,在340 nm激发波长下测量荧光强度。以相对荧光强度[(F0-F)/F0]为纵坐标,Ag+浓度为横坐标做曲线,其中, F0和F分别表示在不存在和存在Ag+的情况下Cu NCs的荧光强度。为了研究Ag+的选择性,分别测定Cu NCs对不同阳离子(包括Na+, K+, Mg2+, Ca2+, Ba2+, Al3+, Zn2+, Pb2+, Cr3+, Ni2+, Cd2+, Co2+, Fe3+, Fe2+, Hg2+)和阴离子(F-, Cl-, Br-, I-, S2-, NO3-, NO2-, SO42-, CO32-, SO32-, Ac-, C2O42-)的荧光响应。

    实际水样主要采自实验室水龙头水样和学校的湖水。将所有样品离心(10000 r/min)并通过0.22 μm滤膜进行过滤以除去任何悬浮颗粒。加入各种标准浓度的Ag+溶液。随后,与Cu NCs溶液混合(Ag+的最终浓度为5、15、25 μmol/L),5 min后记录荧光强度。

    2.1.1   铜纳米团簇的TEM和XPS表征

    为了阐明Cu NCs的纳米结构和主要组成,分别采用TEM和XPS对Cu NCs进行表征,结果如图 1所示。由图 1A可见,Cu NCs具有较高的分散性,尺寸大小为2~3 nm。而且,由于2-巯基苯并咪唑充当保护剂,没有明显形成较大尺寸的铜纳米颗粒或聚集。为了深入了解Cu NCs的主要组分,采用XPS进行表征。由图 1B可见,明显出现了Na (1s)、Cu(2p)、O(1s)、Na(KLL)、N(1s)、C(1s)和S(2p)7个主峰。结果表明:Cu NCs主要由S、C、N、O、Na和Cu组成。由图 1C可见,铜的XPS单谱中在932.2和952.7 eV处观察到两个峰,它们分别对应于Cu(0)的2p3/2和2p1/2的电子结合能。且在942 eV附近未出现峰,表明Cu(II)被完全还原。

    图 1

    图 1.  (A) 铜纳米团簇的TEM;(B)铜纳米团簇的XPS谱图;(C)Cu2p的XPS谱图
    Figure 1.  (A)TEM image of Cu NCs. (B)XPS spectrum of Cu NCs. (C)XPS spectrum of Cu2p
    2.1.2   铜纳米团簇的紫外可见和荧光表征

    采用紫外可见光谱和荧光光谱对Cu NCs的光学特性进行分析,结果如图 2所示。由图 2A可见,Cu NCs的最大激发和发射波长分别为340和559 nm,Cu NCs的紫外可见光谱中在300 nm附近有明显吸收峰,在500~600 nm处未发现吸收峰,表明所合成的铜纳米团簇中无较大颗粒的铜粒子。而且Cu NCs水溶液在日光下呈淡黄色,在紫外可见光下发出橙色荧光。此外,Cu NCs在320 nm至380 nm不同激发波长范围内最大发射波长无明显变化(图 2B),表明Cu NCs分散性比较好。

    图 2

    图 2.  (A) Cu NCs的紫外吸收光谱(a)、荧光激发光谱(b)和荧光发射光谱(c); (B)Cu NCs在320 nm至380 nm不同激发下的发射光谱
    Figure 2.  (A)UV-Vis absorption spectra(a), the fluorescence excitation(b) and emission spectra(c) of Cu NCs; (B)The fluorescence emission spectra of Cu NCs at different excitation wavelengthes from 320 nm to 380 nm

    采用化学还原法以硝酸铜、2-巯基苯并咪唑、聚乙烯吡咯烷酮、水合肼为原料制备Cu NCs,为了获得荧光强度最强的Cu NCs,考察了2-巯基苯并咪唑、聚乙烯吡咯烷酮和水合肼的用量、反应时间和溶液pH值对其荧光强度的影响,研究结果如图 3所示。由图 3可见,最优的反应条件为2-巯基苯并咪唑的体积为4 mL,聚乙烯吡咯烷酮为4 mL,水合肼的体积为4 mL,反应时间为15 min和pH=13。

    图 3

    图 3.  Cu NCs制备条件的优化
    Figure 3.  The fluorescence intensity of Cu NCs in different synthetic conditions

    A.the amount of 2-Mercaptobenzimidazole (varying from 3 to 7 mL); B.the amount of PVP (varying from 2 to 6 mL); C.the amount of hydrazine hydrate (varying from 0.5 to 2.5 mL); D.the reaction time (varying from 5 to 25); (E)pH value (varying from 5 to 13)

    良好的水溶性和强荧光强度有利于Cu NCs更好地在实际生活中应用。此外,Cu NCs的稳定性是至关重要的。因此,研究了储存时间、紫外光照时间和氯化钠浓度对Cu NCs的荧光强度的影响,如图 4所示。由图 4A可见,Cu NCs在4 ℃储存7 d后荧光强度无明显变化。还研究了Cu NCs的光稳定性,暴露于375 nm的紫外灯1 h后,Cu NCs的荧光强度保持稳定(图 4B)。此外,即使在250 mmol/L NaCl溶液中,荧光强度也只是略有变化。可见,该Cu NCs具有很好的光稳定性和较强的抗氯化钠干扰性。

    图 4

    图 4.  储存时间(A)、紫外照射时间(B)和氯化钠(C)对Cu NCs荧光强度的影响
    Figure 4.  Effect of storage time(A), UV-light illumination time(B), concentrations of NaCl(C) on the fluorescence intensity of Cu NCs

    首先考察了pH值对检测银的影响,如图 5A所示,当溶液的pH=13时,铜纳米团簇的荧光猝灭程度达到最大。此外,在最佳条件下研究了Cu NCs检测Ag+的灵敏性。如图 5B所示,随着Ag+浓度从0增加到100 μmol/L,Cu NCs的荧光强度逐渐降低。相对荧光强度(F0-F)/F0与Ag+的浓度在1~40 μmol/L的范围内表现出良好的线性关系(图 5D)。拟合的线性曲线可以表示为(F0-F)/F0=0.01331[Ag+]-0.0044(R2=0.9961,n=10)(其中,F和F0分别是存在和不存在Ag+情况下的荧光强度),银离子的检测限为0.5 μmol/L。

    图 5

    图 5.  (A) pH值对Cu NCs检测Ag+的影响;(B)不同Ag+浓度所对应Cu NCs的荧光光谱;(C)相对荧光强度与Ag+浓度(0~100 μmol/L)的关系;(D)相对荧光强度与Ag+浓度(1~40 μmol/L)的线性关系
    Figure 5.  (A)The effect of pH on the detection of Ag+ by using Cu NCs. (B)Fluorescence emission spectra of Cu NCs with the addition of different Ag+ concentrations. (C)Plot of the (F0-F)/F0 vs Ag+ concentrations increasing 0 to 100 μmol/L. (D)The calibration plot of (F0-F)/F0 vs Ag+ concentrations range from 1 to 40 μmol/L

    为了研究Cu NCs探针的离子选择性,研究了各种离子对Cu NCs荧光强度的影响,结果如图 6所示。其中金属离子包括Na+、K+、Mg2+、Ca2+、Ba2+、Al3+、Zn2+、Pb2+、Cr3+、Ni2+、Cd2+、Co2+、Fe3+、Fe2+和Hg2+;非金属离子包括F-、Cl-、Br-、I-、S2-、NO3-、NO2-、SO42-、CO32-、SO32-、Ac-和C2O42-。由图 6A和6B可见,加入其它离子后Cu NCs的荧光强度均没有发生明显变化,而加入银离子和汞离子后荧光发生猝灭,且银离子的猝灭程度高于汞离子。可见,基于Cu NCs的传感系统对检测Ag+具有出色的选择性。

    图 6

    图 6.  在不同金属离子(A)和非金属离子(B)存在下Cu NCs的相对荧光强度
    Figure 6.  Relative FL intensities of Cu NCs at 559 nm with addition of different metal ions(A) and non-metal ions(B)

    已有文献报道,铜纳米团簇用于检测Hg2+[27]和Fe3+[28]的主要机理为Hg2+和Fe3+与纳米团簇的保护链发生相互作用,使得纳米团簇发生聚集,进而使纳米团簇的荧光发生猝灭。对加入Ag+后的铜纳米团簇进行TEM分析,如图 7所示。由图 7可见,加入Ag+后,铜纳米团簇发生明显的团聚现象,可见,猝灭机理主要为Ag+与铜纳米团簇的保护剂2-巯基苯并咪唑中的巯基发生相互作用。

    图 7

    图 7.  加入银离子后铜纳米团簇的TEM照片
    Figure 7.  TEM image of Cu NCs in the presence of Ag+

    基于该铜纳米团簇在银离子检测中表现出优异的灵敏度和选择性,将该传感器应用于实际水样中银离子的检测。水样经离心(10000 r/min)和0.22 μm滤膜进行过滤以除去所含悬浮颗粒,取上清液进行测试,并进行了样品加标回收实验,结果如表 1所示,其回收率在97.6%~107.6%之间。结果表明,本方法可以成功应用于实际水样中银离子的检测分析。

    表 1

    表 1  水样中Ag+的测定(n=3)
    Table 1.  Determination of Ag+ in spiked water samples(n=3)
    下载: 导出CSV
    Sample source No. Added/(mol·L-1) Found/(mmol·L-1) Recovery /%
    Tap water 1 5 4.88 97.6
    2 15 15.02 100.1
    3 25 26.2 104.8
    Lake water 1 5 5.18 103.6
    2 15 14.88 99.2
    3 25 26.89 107.6

    本文以2-巯基苯并咪唑为保护剂,聚乙烯吡咯烷酮为稳定剂,水合肼为还原剂,通过“一锅法”合成2-巯基苯并咪唑保护的水溶性铜纳米团簇,具有稳定性高、荧光强、斯托克斯位移大等优点。Cu NCs具有很好的分散性,尺寸大小为2~3 nm。最大激发和发射波长分别为340和559 nm。作为检测银离子的荧光探针,具有很高的灵敏度和选择性。检测银离子的线性范围为1~40 μmol/L,检测限为0.5 μmol/L,且已成功地用于检测实际水样中的银离子。


    1. [1]

      Vasileiadis S, Brunetti G, Marzouk E. Silver Toxicity Thresholds for Multiple Soil Microbial Biomarkers[J]. Environ Sci Technol, 2018, 52(15):  8745-8755. doi: 10.1021/acs.est.8b00677

    2. [2]

      Zhang J F, Zhou Y, Yoon J. Recent Progress in Fluorescent and Colorimetric Chemosensors for Detection of Precious Metal Ions(Silver, Gold and Platinum Ions)[J]. Chem Soc Rev, 2011, 40(7):  3416-3429. doi: 10.1039/c1cs15028f

    3. [3]

      Leslee D B C, Karuppannan S, Karmegam M V. A Fluorescent Turn-On Carbazole-Rhodanine Based Sensor for Detection of Ag+ Ions and Application in Ag+ Ions Imaging in Cancer Cells[J]. J Fluoresc, 2019, 29(1):  75-89. doi: 10.1007/s10895-018-2312-6

    4. [4]

      Xie Y F, Cheng Y Y, Liu M L. A Single Gold Nanoprobe for Colorimetric Detection of Silver(I) Ions with Dark-Field Microscopy[J]. Analyst, 2019, 144(6):  2011-2016. doi: 10.1039/C8AN02397B

    5. [5]

      Baron M G, Herrin R T, Armstrong D E. The Measurement of Silver in Road Salt by Electrothermal Atomic Absorption Spectrometry[J]. Analyst, 2000, 125(1):  123-126.

    6. [6]

      Manzoori J L, Abdolmohammad-Zadeh H, Amjadi M. Ultra-trace Determination of Silver in Water Samples by Electrothermal Atomic Absorption Spectrometry after Preconcentration with a Ligand-less Cloud Point Extraction Methodology[J]. J Hazard Mater, 2007, 144(1/2):  458-463.

    7. [7]

      Mohadesi A, AliTaher M. Stripping Voltammetric Determination of Silver(I) at Carbon Paste Electrode Modified with 3-Amino-2-mercapto Quinazolin-4(3H)-one[J]. Talanta, 2007, 71(2):  615-619. doi: 10.1016/j.talanta.2006.05.001

    8. [8]

      Singh R P, Pambid E R. Selective Separation of Silver from Waste Solutions on Chromium(III) Hexacyanoferrate(III) Ion Exchanger[J]. Analyst, 1990, 115(3):  301-304.

    9. [9]

      Katarina R K, Takayanagi T, Oshima M. Synthesis of a Chitosan-Based Chelating Resin and Its Application to the Selective Concentration and Ultratrace Determination of Silver in Environmental Water Samples[J]. Anal Chim Acta, 2006, 558(1/2):  246-253.

    10. [10]

      Ceresa A, Radu A, Peper S. Rational Design of Potentiometric Trace Level Ion Sensors. A Ag+-Selective Electrode with a 100 ppt Detection Limit[J]. Anal Chem, 2002, 74(16):  4027-4036. doi: 10.1021/ac025548y

    11. [11]

      Kamel G M, El-Nahass M N, El-Khouly M E. Simple, Selective Detection and Efficient Removal of Toxic Lead and Silver Metal Ions Using Acid Red 94[J]. RSC Adv, 2019, 9(15):  8355-8363. doi: 10.1039/C9RA00464E

    12. [12]

      Liu Z X, Liu Y M, Lu S H. A Highly Selective TPE-based AIE Fluorescent Probe is Developed for the Detection of Ag+[J]. RSC Adv, 2018, 8(35):  19701-19706. doi: 10.1039/C8RA03591A

    13. [13]

      Jiang Y B, Gao C, Zhang X. A Highly Selective and Sensitive Fluorescence Probe with A-π-D-π-A Structure for Detection of Ag+[J]. J Mol Struct, 2018, 1163:  33-40. doi: 10.1016/j.molstruc.2018.01.058

    14. [14]

      Wei G, Jiang Y L, Wang F. A Novel AIEE Polymer Sensor for Detection of Hg2+ and Ag+ in Aqueous Solution[J]. J Photochem Photobiol A, 2018, 358:  38-43. doi: 10.1016/j.jphotochem.2018.03.006

    15. [15]

      Li M Q, Liao H W, Deng Q L. Preparation of an Intelligent Hydrogel Sensor Based on g-C3N4 Nanosheets for Selective Detection of Ag+[J]. J Macromol Sci A, 2018, 55(5):  408-413. doi: 10.1080/10601325.2018.1453260

    16. [16]

      Jiang X D, Xu W C, Chen X. Colorimetric Assay for Ultrasensitive Detection of Ag(I) Ions Based on the Formation of Gold Nanoparticle Oligomers[J]. Anal Bioanal Chem, 2019, 411(11):  2439-2445. doi: 10.1007/s00216-019-01685-6

    17. [17]

      Guo Y M, Cao F P, Lei X L. Fluorescent Copper Nanoparticles:Recent Advances in Synthesis and Applications for Sensing Metal Ions[J]. Nanoscale, 2016, 8(9):  4852-4863. doi: 10.1039/C6NR00145A

    18. [18]

      Yang K C, Wang Y Y, Lu C S. Ovalbumin-directed Synthesis of Fluorescent Copper Nanoclusters for Sensing both Vitamin B1 and Doxycycline[J]. J Fluoresc, 2018, 196:  181-186.

    19. [19]

      Tang T, Ouyang J, Hu L S. Synthesis of Peptide Templated Copper Nanoclusters for Fluorometric Determination of Fe(III) in Human Serum[J]. Microchim Acta, 2016, 183(10):  2831-2836. doi: 10.1007/s00604-016-1935-z

    20. [20]

      Wang C X, Cheng H, Huang Y J. Facile Sonochemical Synthesis of pH-Responsive Copper Nanoclusters for Selective and Sensitive Detection of Pb2+ in Living Cells[J]. Analyst, 2015, 140(16):  5634-5639. doi: 10.1039/C5AN00741K

    21. [21]

      Aparna R S, Syamchand S S, George S. Tannic Acid Stabilised Copper Nanocluster Developed Through Microwave Mediated Synthesis as a Fluorescent Probe for the Turn on Detection of Dopamine[J]. J Clust Sci, 2017, 28(4):  2223-2238. doi: 10.1007/s10876-017-1221-1

    22. [22]

      Gui R J, Sun J, Cao X L. Multidentate Polymers Stabilized Water-Dispersed Copper Nanoclusters:Facile Photoreduction Synthesis and Selective Fluorescence Turn-on Response[J]. RSC Adv, 2014, 4(55):  29083-29088. doi: 10.1039/C4RA03606A

    23. [23]

      Bagheri H S, Afkhami A, Khoshsafar H. Protein Capped Cu Nanoclusters-SWCNT Nanocomposite as a Novel Candidate of High Performance Platform for Organophosphates Enzymeless Biosensor[J]. Biosens Bioelectron, 2017, 89(2):  829-836.

    24. [24]

      Zhang Y Y, Li Y X, Zhang C Y. Fluorescence Turn-on Detection of Alkaline Phosphatase Activity Based on Controlled Release of PEI-Capped Cu Nanoclusters from MnO2 Nanosheets[J]. Anal Bioanal Chem, 2017, 409(20):  4771-4778. doi: 10.1007/s00216-017-0420-9

    25. [25]

      Ai L, Jiang W R, Liu Z Y. Engineering a Red Emission of Copper Nanocluster Self-assembly Architectures by Employing Aromatic Thiols as Capping Ligands[J]. Nanoscale, 2017, 9(34):  12618-12627. doi: 10.1039/C7NR03985A

    26. [26]

      Sun J, Yue Y, Wang P. Facile and Rapid Synthesis of Water-Soluble Fluorescent Gold Nanoclusters for Sensitive and Selective Detection of Ag+[J]. J Mater Chem C, 2016, 1:  908-913.

    27. [27]

      Luo T T, Zhang S T, Wang Y J. Glutathione-Stabilized Cu Nanocluster-Based Fluorescent Probe for Sensitive and Selective Detection of Hg2+ in Water[J]. Luminescence, 2017, 32:  1092-1099. doi: 10.1002/bio.3296

    28. [28]

      Jayasree M, Aparna S S, Anjana R R. Fluorescence Turn on Detection of Bilirubin Using Fe(III) Modulated BSA Stabilized Copper Nanocluster; A Mechanistic Perception[J]. Anal Chim Acta, 2018, 1031:  152-160. doi: 10.1016/j.aca.2018.05.026

  • 图 1  (A) 铜纳米团簇的TEM;(B)铜纳米团簇的XPS谱图;(C)Cu2p的XPS谱图

    Figure 1  (A)TEM image of Cu NCs. (B)XPS spectrum of Cu NCs. (C)XPS spectrum of Cu2p

    图 2  (A) Cu NCs的紫外吸收光谱(a)、荧光激发光谱(b)和荧光发射光谱(c); (B)Cu NCs在320 nm至380 nm不同激发下的发射光谱

    Figure 2  (A)UV-Vis absorption spectra(a), the fluorescence excitation(b) and emission spectra(c) of Cu NCs; (B)The fluorescence emission spectra of Cu NCs at different excitation wavelengthes from 320 nm to 380 nm

    图 3  Cu NCs制备条件的优化

    Figure 3  The fluorescence intensity of Cu NCs in different synthetic conditions

    A.the amount of 2-Mercaptobenzimidazole (varying from 3 to 7 mL); B.the amount of PVP (varying from 2 to 6 mL); C.the amount of hydrazine hydrate (varying from 0.5 to 2.5 mL); D.the reaction time (varying from 5 to 25); (E)pH value (varying from 5 to 13)

    图 4  储存时间(A)、紫外照射时间(B)和氯化钠(C)对Cu NCs荧光强度的影响

    Figure 4  Effect of storage time(A), UV-light illumination time(B), concentrations of NaCl(C) on the fluorescence intensity of Cu NCs

    图 5  (A) pH值对Cu NCs检测Ag+的影响;(B)不同Ag+浓度所对应Cu NCs的荧光光谱;(C)相对荧光强度与Ag+浓度(0~100 μmol/L)的关系;(D)相对荧光强度与Ag+浓度(1~40 μmol/L)的线性关系

    Figure 5  (A)The effect of pH on the detection of Ag+ by using Cu NCs. (B)Fluorescence emission spectra of Cu NCs with the addition of different Ag+ concentrations. (C)Plot of the (F0-F)/F0 vs Ag+ concentrations increasing 0 to 100 μmol/L. (D)The calibration plot of (F0-F)/F0 vs Ag+ concentrations range from 1 to 40 μmol/L

    图 6  在不同金属离子(A)和非金属离子(B)存在下Cu NCs的相对荧光强度

    Figure 6  Relative FL intensities of Cu NCs at 559 nm with addition of different metal ions(A) and non-metal ions(B)

    图 7  加入银离子后铜纳米团簇的TEM照片

    Figure 7  TEM image of Cu NCs in the presence of Ag+

    表 1  水样中Ag+的测定(n=3)

    Table 1.  Determination of Ag+ in spiked water samples(n=3)

    Sample source No. Added/(mol·L-1) Found/(mmol·L-1) Recovery /%
    Tap water 1 5 4.88 97.6
    2 15 15.02 100.1
    3 25 26.2 104.8
    Lake water 1 5 5.18 103.6
    2 15 14.88 99.2
    3 25 26.89 107.6
    下载: 导出CSV