Citation: REN Ju-Jie, YU Cong-Cong, CUI Min, LI Ya-Qing, WU Cong, JI Xue-Ping. Construction of Hemin Composite Based Electrochemical Sensor for Detection of Peroxynitrite[J]. Chinese Journal of Analytical Chemistry, 2017, 45(1): 104-110. doi: 10.11895/j.issn.0253-3820.160597
基于氯化血红素复合材料的过氧亚硝酸阴离子电化学传感器的构建
English
Construction of Hemin Composite Based Electrochemical Sensor for Detection of Peroxynitrite
-
Key words:
- Peroxynitrite
- / Hemin
- / Poly(melamine)
- / Gold nanoparticles
- / Multi-walled carbon nanotubes
- / Electrochemical sensor
-
-
[1]
JING Xiao-Tong, YU Fa-Biao, CHEN Ling-Xin. Prog. Chem., 2014,26(5):866-878景晓彤,于法标,陈令新.化学进展,2014,26(5):866-878
-
[2]
ZHENG Rong-Liang, HUANG Zhong-Yang. Free Radical Biology, Beijing:Higher Education Press, 2007:33郑荣梁,黄中洋.自由基生物学,北京:高等教育出版社, 2007:33
-
[3]
Peteu S F, Boukherroub R, Szunerits S. Biosens. Bioelectron., 2014,58(16):359-373
-
[4]
Ohshima H, Tatemichi M, Sawa T. Arch. Biochem. Biophys., 2003,417(1):3-11
-
[5]
Deeb R S, Resnick M J, Mittar D, Mccaffrey T, Hajjar D P, Upmacis R K. J. Lipid. Res., 2002,43(10):1718-1726
-
[6]
Van't Hof R J, Ralston S H. Immunology, 2001,11(3):255-261
-
[7]
Torreilles F, Salman-Tabcheh S, Guérin M C, Torreilles J. Brain Res. Rev., 1999,30(2):153-163
-
[8]
Wang Y, Chen Z Z. Talanta, 2010, 82(2):534-539
-
[9]
Peteu S F, Bose T, Bayachou M. Anal. Chim. Acta, 2013,780(10):81-88
-
[10]
Vandervliet A, Eiserich J P, Oneill C A, Halliwell B, Cross C E. Arch. Biochem. Biophys., 1995,319(2):341-349
-
[11]
Wang B S, Yu F B, Li P, Sun X F, Han K L. Dyes Pigments, 2013,96(2):383-390
-
[12]
Ma J J, Wu J S, Liu W M, Wang P F, Fan Z Y. Spectrochim. Acta. A., 2012,94(8):340-345
-
[13]
Jia X T, Chen Q Q, Yang Y F, Tang Y, Wang R, Xu Y F, Zhu W P, Qian X H. J. Am. Chem. Soc., 2016,138(34):10778-10781
-
[14]
Dai K, Vlessidis A G, Evmiridis N P. Talanta, 2003,59(1):55-65
-
[15]
Adegoke O, Nyokong T. J. Lumin., 2013,134(2):448-455
-
[16]
Dikalov S, Skatchkov M, Bassenge E. Biochem. Bioph. Res. Co., 1997,230(1):54-57
-
[17]
Gielis J F, Boulet G A, Briedé J J, Horemans T, Debergh T, Kussé M, Cos P, van Schil P E Y. Eur. J. Cardio-Thorac., 2015,48(4):622-629
-
[18]
Imaram W, Gersch C, Kim K M, Johnson R J, Henderson G N, Angerhofer A. Free Radical. Bio. Med., 2010,49(2):275-281
-
[19]
Cortés J S, Granados S G, Ordaz A A, López Jiménez J A, Griveau S, Bedioui F. Electroanal, 2007,19(1):61-64
-
[20]
Quinton D, Griveau S, Bedioui F. Electrochem. Commun., 2010,12(10):1446-1449
-
[21]
Peteu S, Peiris P, Gebremichael E, Bayachou M. Biosens. Bioelectron., 2010,25(8):1914-1921
-
[22]
Koh W C, Son J I, Choe E S, Shim Y B. Anal. Chem., 2010,82(24):10075-10082
-
[23]
Oprea R, Peteu S F, Subramanian P, Wang Q, Pichonat E, Happy H, Bayachou M, Boukherroub R, Szunerits S. Analyst, 2013,138(15):4345-4352
-
[24]
Peteu S F, Whitman B W, Galligan J J, Swain G M. Analyst, 2016,141(5):1796-1806
-
[25]
Cheng F Y, Adronov A. Chem-Eur. J., 2006,12(19):5053-5059
-
[26]
Beckman J S, Chen J, Ischiropoulos H, Crow J P. Method. Enzymol., 1994,233(23):229-240
-
[27]
LI Qi-Long, HU Jin-Bo. Electroanalytical Chemistry. Beijing:Beijing Normal University Press, 2007:444李启隆,胡劲波.电分析化学,北京:北京师范大学出版社, 2007:444
-
[28]
HUANG Xiu-Ling, WANG Qi-Hui, LIU Hui-Hong. J. Analyt. Sci., 2008,24(1):55-58黄秀玲,王启会,刘慧宏.分析科学学报,2008,24(1):55-58
-
[29]
Guo Y J, Deng L, Li J, Guo S J, Wang E K, Dong S J. Acs Nano, 2011,5(2):1282-1290
-
[30]
Singh S K, Singh M K, Kulkarni P P, Sonkar V K, Grácio J J A, Dash D. Acs Nano, 2012,6(3):2731-2740
-
[31]
Lipińska M E, Rebelo S L H, Pereira M F R, Gomes J A N F, Freire C, Figueiredo J L. Carbon, 2012,50(9):3280-3294
-
[1]
-
扫一扫看文章
计量
- PDF下载量: 4
- 文章访问数: 1178
- HTML全文浏览量: 69

下载: