基于石墨烯信号放大策略的胆固醇分子印迹电化学传感器研究

白慧萍 ,  王春琼 ,  曹秋娥

引用本文: 白慧萍,  王春琼,  曹秋娥. 基于石墨烯信号放大策略的胆固醇分子印迹电化学传感器研究[J]. 分析化学, 2017, 45(10): 1535-1541. doi: 10.11895/j.issn.0253-3820.170215 shu
Citation:  BAI Hui-Ping,  WANG Chun-Qiong,  CAO Qiu-E. Molecularly Imprinted Electrochemical Sensor for Determination of Cholesterol Based on Signal Amplification of Graphene[J]. Chinese Journal of Analytical Chemistry, 2017, 45(10): 1535-1541. doi: 10.11895/j.issn.0253-3820.170215 shu

基于石墨烯信号放大策略的胆固醇分子印迹电化学传感器研究

  • 基金项目:

    本文系云南省教育厅科学基金(No.2017ZZX231)和国家自然科学基金项目(Nos.21465025,21505119)资助

摘要: 利用石墨烯的信号放大作用,结合分子印迹技术和电聚合技术,以苯酚为功能单体,胆固醇(ChO)为模板分子,在石墨烯修饰的玻碳电极表面电聚合能识别胆固醇分子的敏感膜,构建胆固醇分子印迹电化学传感器。采用扫描电镜、循环伏安法、差分脉冲伏安法研究了印迹膜的结构、性能和分子印迹效应。结果表明,此传感器对胆固醇有良好的选择性和较高的灵敏度。胆固醇浓度在8.0×10-8~2.0×10-4 mol/L范围内与峰电流的变化呈线性关系,检出限(S/N=3)为5.6×10-8 mol/L。将其用于人体血清样品的检测,结果满意。

English

    1. [1]

      Zhang H F, Liu R X, Zheng J B. Analyst, 2012,137(22):5363-5367

    2. [2]

      Lin X Y, Ni Y N, Kokot S. Sens. Actuators B, 2016, 233(10):100-106

    3. [3]

      Odo J, Inoguchi M, Ohira S, Tsukikawa S, Aramaki M, Matsuhama S, Taito M, Takayama A. Anal. Sci., 2013, 29(11):1041-1048

    4. [4]

      Lotfy H M, Hegazy M A M. Spectrochim. Acta A, 2013, 113(9):107-114

    5. [5]

      Hayat A, Haider W, Raza Y, Marty J L. Talanta, 2015, 143:157-161

    6. [6]

      Zhang Y, Wang Y N, Sun X T, Chen L, Xu Z R. Sens. Actuators B, 2017, 246:118-126

    7. [7]

      Clausen D N, Visentainer J V, Tarley C R T. Analyst, 2014, 139(19):5021-5027

    8. [8]

      HAO Wan-Peng, XU Lei. J. Mod. Lab. Med., 2005, 20(2):27-29 郝万鹏, 徐 磊.现代检验医学杂志, 2005, 20(2):27-29[LM]

    9. [9]

      KE Xing, HUANG Bai-Fen, LYU Mei-Lin, MO Wei-Min, REN Yi-Ping. Chinese J. Anal. Chem.,2015,43(12):1920-1926 柯 星, 黄百芬, 吕美玲, 莫卫民, 任一平.分析化学,2015,43(12):1920-1926

    10. [10]

      Ruecha N, Rangkupan R, Rodthongkum N, Chailapakul O. Biosens. Bioelectron., 2014, 52(2):13-19

    11. [11]

      Martín M, Salazar P, Álvarez R, Palmero A, López-Santos C, González-Mora J L, González-Elipe A R. Sens. Actuators B, 2017, 240(3):37-45

    12. [12]

      Dervisevic M, Çevik E, Çenel M, Nergiz C, Abasiyanik M F. J. Electroanal. Chem., 2016, 776(9):18-24

    13. [13]

      Huang Y, Cui L J, Xue Y W, Zhang S B, Zhu N X, Liang J T, Li G Y. Mat. Sci. Eng. C, 2017 In Press

    14. [14]

      Ji R, Wang L, Wang G, Zhang X. Electrochim. Acta, 2014, 130(6):239-244

    15. [15]

      Yang L, Yang J, Xu B J, Zhao F Q, Zeng B Z. Talanta, 2016, 161:413-418

    16. [16]

      CHEN Xiao, TAN Xue-Cai, YAN Jun, WU Ye-Yu, WU Ye-Yu, LI Xiao-Yu, ZHANG Hui, CHEN Quan-You, FENG De-Fen, JIN Ying-Xin. Chinese J. Anal. Chem., 2016, 44(12):1834-1839 陈 晓, 谭学才, 严 军, 吴叶宇, 李晓宇, 张 慧, 陈全友, 冯德芬, 金应鑫.分析化学, 2016, 44(12):1834-1839

    17. [17]

      Li J B, Wang X J, Duan H M, Wang Y H, Bu Y N, Luo C N. Talanta, 2016, 147:169-176

    18. [18]

      Kong L, Jiang X Y, Zeng Y B, Zhou T S, Shi G Y. Sens. Actuators B, 2013, 185(8):424-431

    19. [19]

      Xie C G, Zhou H K, Gao S, Li H F. Microchim. Acta,2010, 171(3-4):355-362

    20. [20]

      Matsui J, Miyoshi Y, Doblhoff-Dier O, Takeuchi T. Anal. Chem., 1995, 67(23):4404-440

  • 加载中
计量
  • PDF下载量:  9
  • 文章访问数:  1167
  • HTML全文浏览量:  114
文章相关
  • 收稿日期:  2017-04-05
  • 修回日期:  2017-08-07
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

/

返回文章