引用本文:
Qiao Hua Wei, Li Jing Han, Jing Hua Chen, Fang Nan Xiao, Shen Liang Zeng, Guo Nan Chen. Electrochemical behavior of Ru(H2bpp)2(PF6)2 and its interaction with bovine serum albumin(BSA)[J]. Chinese Chemical Letters,
2011, 22(6): 713-716.
doi:
10.1016/j.cclet.2010.12.040
Citation: Qiao Hua Wei, Li Jing Han, Jing Hua Chen, Fang Nan Xiao, Shen Liang Zeng, Guo Nan Chen. Electrochemical behavior of Ru(H2bpp)2(PF6)2 and its interaction with bovine serum albumin(BSA)[J]. Chinese Chemical Letters, 2011, 22(6): 713-716. doi: 10.1016/j.cclet.2010.12.040
Citation: Qiao Hua Wei, Li Jing Han, Jing Hua Chen, Fang Nan Xiao, Shen Liang Zeng, Guo Nan Chen. Electrochemical behavior of Ru(H2bpp)2(PF6)2 and its interaction with bovine serum albumin(BSA)[J]. Chinese Chemical Letters, 2011, 22(6): 713-716. doi: 10.1016/j.cclet.2010.12.040
Electrochemical behavior of Ru(H2bpp)2(PF6)2 and its interaction with bovine serum albumin(BSA)
摘要:
In this paper, it was found that Ru(H2bpp)2(PF6)2(H2bpp=2,6-bis(pyrazol-3-yl)pyridine)complex had excellent electrochemical activity at the carbon paste electrode in the buffer solution of Tris-HCl(pH 7.0)with a couple reversible redox peaks at 0.296 V and 0.348 V, respectively.Voltammetry was used to investigate the electrochemical behavior of Ru(H2bpp)2(PF6)2 and the interaction between Ru(H2bpp)2(PF6)2 and bovine serum albumin(BSA).In the present of BSA, the oxidation peak current of Ru(H2bpp)2(PF6)2 complex was decreased linearly and the decrease of oxidation peak current of Ru(H2bpp)2(PF6)2 is proportional to BSA concentration from 0.1 to 2.5 mg/L with a detection limit 0.02 mg/L.
English
Electrochemical behavior of Ru(H2bpp)2(PF6)2 and its interaction with bovine serum albumin(BSA)
Abstract:
In this paper, it was found that Ru(H2bpp)2(PF6)2(H2bpp=2,6-bis(pyrazol-3-yl)pyridine)complex had excellent electrochemical activity at the carbon paste electrode in the buffer solution of Tris-HCl(pH 7.0)with a couple reversible redox peaks at 0.296 V and 0.348 V, respectively.Voltammetry was used to investigate the electrochemical behavior of Ru(H2bpp)2(PF6)2 and the interaction between Ru(H2bpp)2(PF6)2 and bovine serum albumin(BSA).In the present of BSA, the oxidation peak current of Ru(H2bpp)2(PF6)2 complex was decreased linearly and the decrease of oxidation peak current of Ru(H2bpp)2(PF6)2 is proportional to BSA concentration from 0.1 to 2.5 mg/L with a detection limit 0.02 mg/L.
-
Key words:
- Ru(H2bpp)2(PF6)2
- / Electrochemistry
- / Bovine serum al
扫一扫看文章
计量
- PDF下载量: 0
- 文章访问数: 1520
- HTML全文浏览量: 43

下载: