Citation: WANG Mengying,  CHEN Yechao,  TU Fengqin,  HOU Jing,  YANG Ming,  LU Yuepeng,  WANG Yuhong,  YANG Zong,  CHEN Dan. Screening and quantitative analysis of nine illicit antiallergics in emulsion cosmetics by ultra-high performance liquid chromatography-quadrupole-time-of-flight high-resolution mass spectrometry[J]. Chinese Journal of Chromatography, ;2020, 38(12): 1423-1430. doi: 10.3724/SP.J.1123.2020.06017 shu

Screening and quantitative analysis of nine illicit antiallergics in emulsion cosmetics by ultra-high performance liquid chromatography-quadrupole-time-of-flight high-resolution mass spectrometry

  • Corresponding author: CHEN Dan, 2010103010012@whu.edu.cn
  • Received Date: 12 June 2020

    Fund Project: Research Project of Hubei Food and Drug Administration (No. 201801020).

  • A rapid and accurate analysis method based on ultra-high performance liquid chromatography coupled with quadrupole-time-of-flight high-resolution mass spectrometry (UPLC-Q-TOF-HRMS) was developed to screen and determine nine antiallergy drugs in emulsion cosmetics. First, a standard library of the target compounds was established. The library contained the TOF-MS information and secondary MS information such as retention time, ion addition mode, mass error, isotope distribution, mass-to-charge ratio of the parent ion, and fragment ion distribution. According to the European Union regulation (SANTE/11945/2015), the standard for the qualitative determination by HRMS was determined; that is, each compound was confirmed by two ions with a mass error below 5%, and the abundance ratio of the two ions was less than 30%. Second, the instrument conditions and sample pretreatment conditions for the determination of different compounds were optimized, and the influence of different levels of quantitative ions on the matrix effect was compared. The following observations were made:(1) the addition of 0.1% formic acid to the water phase improved the response of the chromatographic peaks; (2) among the various solvent amounts tested (4, 5, 6, 8 mL acetonitrile and 4, 5, 6, 8 mL methanol), 4 mL acetonitrile showed the best extraction efficiency; (3) PRiME HLB had a better purification effect than the other two purification columns (C18 and HLB solid-phase extraction cartridges), thus reducing the interference of impurities and ensuring good recovery of the target compounds; (4) the use of two pairs of secondary product ion quantification could significantly reduce the matrix effect of anti-allergic compounds and improve the quantification accuracy. Finally, based on the above findings, the experimental procedure was established. The lotion samples were first ultrasonically extracted with acetonitrile and purified on the PRiME HLB column. Chromatographic separation was performed on a Waters XBridge C18 column with gradient elution using 0.1% (v/v) formic acid in water and acetonitrile. Finally, the sequential window acquisition of all theoretical mass spectra (SWATH), which shows obvious advantages in continuous and high-throughput acquisition, was selected for MS data acquisition. The retention time, mass accuracy, isotope distribution, and fragment ion matching ratio were used for fast qualitative screening, while the peak areas of characteristic product ions were used for precise quantification. All the calibration curves showed good linearity (r2>0.99) within the tested ranges (5-100 μg/L) under the optimum conditions. The limits of quantification (LOQs) were in the range of 0.05-0.10 mg/kg. The recoveries were in the range of 65.3%-107% at three spiked levels (0.10, 0.20, and 0.60 mg/kg), with relative standard deviations (RSDs, n=6) below 20%. Compared with the existing ion exchange column methods, the proposed "one-step" purification method based on PRiME HLB is simpler and more rapid, where the extraction solution is filtered directly after allowing it to pass through the column, without any subsequent washing and elution procedures. In addition, the LOQs of this method are lower than those of other LC-MS/MS methods, indicating that the proposed method has higher sensitivity. The application of SWATH data acquisition makes it possible to achieve quantification with two pairs of product ions, thus reducing the matrix effect and ensuring accuracy of the quantitative results. Therefore, the proposed method is less time-consuming and operationally convenient, and it can be used for the rapid screening and accurate quantification of antiallergics in lotion samples.
  • 加载中
    1. [1]

    2. [2]

    3. [3]

    4. [4]

    5. [5]

    6. [6]

    7. [7]

    8. [8]

    9. [9]

    10. [10]

    11. [11]

    12. [12]

    13. [13]

    14. [14]

    15. [15]

    16. [16]

    17. [17]

  • 加载中
    1. [1]

      Zhenjun Mao Haorui Gu Haiyan Che Xufeng Lin . Exploration on Experiment Teaching of UHPLC-IC Based on Valve Switching Method. University Chemistry, 2024, 39(4): 81-86. doi: 10.3866/PKU.DXHX202311013

    2. [2]

      Yanhui Zhong Ran Wang Zian Lin . Analysis of Halogenated Quinone Compounds in Environmental Water by Dispersive Solid-Phase Extraction with Liquid Chromatography-Triple Quadrupole Mass Spectrometry. University Chemistry, 2024, 39(11): 296-303. doi: 10.12461/PKU.DXHX202402017

    3. [3]

      Zian Lin Yingxue Jin . Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry (MALDI-MS) for Disease Marker Screening and Identification: A Comprehensive Experiment Teaching Reform in Instrumental Analysis. University Chemistry, 2024, 39(11): 327-334. doi: 10.12461/PKU.DXHX202403066

    4. [4]

      Zunxiang Zeng Yuling Hu Yufei Hu Hua Xiao . Analysis of Plant Essential Oils by Supercritical CO2Extraction with Gas Chromatography-Mass Spectrometry: An Instrumental Analysis Comprehensive Experiment Teaching Reform. University Chemistry, 2024, 39(3): 274-282. doi: 10.3866/PKU.DXHX202309069

    5. [5]

      Mingyang Men Jinghua Wu Gaozhan Liu Jing Zhang Nini Zhang Xiayin Yao . 液相法制备硫化物固体电解质及其在全固态锂电池中的应用. Acta Physico-Chimica Sinica, 2025, 41(1): 2309019-. doi: 10.3866/PKU.WHXB202309019

    6. [6]

      Zhiwen HUWeixia DONGQifu BAOPing LI . Low-temperature synthesis of tetragonal BaTiO3 for piezocatalysis. Chinese Journal of Inorganic Chemistry, 2024, 40(5): 857-866. doi: 10.11862/CJIC.20230462

    7. [7]

      Chongjing Liu Yujian Xia Pengjun Zhang Shiqiang Wei Dengfeng Cao Beibei Sheng Yongheng Chu Shuangming Chen Li Song Xiaosong Liu . Understanding Solid-Gas and Solid-Liquid Interfaces through Near Ambient Pressure X-Ray Photoelectron Spectroscopy. Acta Physico-Chimica Sinica, 2025, 41(2): 100013-. doi: 10.3866/PKU.WHXB202309036

    8. [8]

      Yuhao SUNQingzhe DONGLei ZHAOXiaodan JIANGHailing GUOXianglong MENGYongmei GUO . Synthesis and antibacterial properties of silver-loaded sod-based zeolite. Chinese Journal of Inorganic Chemistry, 2024, 40(4): 761-770. doi: 10.11862/CJIC.20230169

    9. [9]

      Pei Li Yuenan Zheng Zhankai Liu An-Hui Lu . Boron-Containing MFI Zeolite: Microstructure Control and Its Performance of Propane Oxidative Dehydrogenation. Acta Physico-Chimica Sinica, 2025, 41(4): 100034-. doi: 10.3866/PKU.WHXB202406012

    10. [10]

      Jiali CHENGuoxiang ZHAOYayu YANWanting XIAQiaohong LIJian ZHANG . Machine learning exploring the adsorption of electronic gases on zeolite molecular sieves. Chinese Journal of Inorganic Chemistry, 2025, 41(1): 155-164. doi: 10.11862/CJIC.20240408

    11. [11]

      Yiping HUANGLiqin TANGYufan JICheng CHENShuangtao LIJingjing HUANGXuechao GAOXuehong GU . Hollow fiber NaA zeolite membrane for deep dehydration of ethanol solvent by vapor permeation. Chinese Journal of Inorganic Chemistry, 2025, 41(2): 225-234. doi: 10.11862/CJIC.20240224

    12. [12]

      Ziheng Zhuang Xiao Xu Kin Shing Chan . Superdrugs for Superbugs. University Chemistry, 2024, 39(9): 128-133. doi: 10.3866/PKU.DXHX202309040

    13. [13]

      Yufang GAONan HOUYaning LIANGNing LIYanting ZHANGZelong LIXiaofeng LI . Nano-thin layer MCM-22 zeolite: Synthesis and catalytic properties of trimethylbenzene isomerization reaction. Chinese Journal of Inorganic Chemistry, 2024, 40(6): 1079-1087. doi: 10.11862/CJIC.20240036

    14. [14]

      Shanghua Li Malin Li Xiwen Chi Xin Yin Zhaodi Luo Jihong Yu . 基于高离子迁移动力学的取向ZnQ分子筛保护层实现高稳定水系锌金属负极的构筑. Acta Physico-Chimica Sinica, 2025, 41(1): 2309003-. doi: 10.3866/PKU.WHXB202309003

    15. [15]

      Hongsheng Tang Yonghe Zhang Dexiang Wang Xiaohui Ning Tianlong Zhang Yan Li Hua Li . A Wonderful Journey through the Kingdom of Hazardous Chemicals. University Chemistry, 2024, 39(9): 196-202. doi: 10.12461/PKU.DXHX202403098

    16. [16]

      Yutong Dong Huiling Xu Yucheng Zhao Zexin Zhang Ying Wang . The Hidden World of Surface Tension and Droplets. University Chemistry, 2024, 39(6): 357-365. doi: 10.3866/PKU.DXHX202312022

    17. [17]

      Gaoyan Chen Chaoyue Wang Juanjuan Gao Junke Wang Yingxiao Zong Kin Shing Chan . Heart to Heart: Exploring Cardiac CT. University Chemistry, 2024, 39(9): 146-150. doi: 10.12461/PKU.DXHX202402011

    18. [18]

      Zhaomei LIUWenshi ZHONGJiaxin LIGengshen HU . Preparation of nitrogen-doped porous carbons with ultra-high surface areas for high-performance supercapacitors. Chinese Journal of Inorganic Chemistry, 2024, 40(4): 677-685. doi: 10.11862/CJIC.20230404

    19. [19]

      Dongxia Zhang Sijia Hao Jiarui Wang Jiwei Wang Xiaogang Dong Liang Jiao . Construction and Reflection on the Safety Management of Hazardous Chemicals in University Laboratories. University Chemistry, 2024, 39(10): 229-235. doi: 10.12461/PKU.DXHX202403078

    20. [20]

      Hengwei Wei Liqiu Zhao Jiqiang Geng Xuebo Xu Yingpeng Ma Yuhao Liu Mingzhe Han Huan Jiao Lingling Wei . Research on Safety Management of Hazardous Chemicals and Talent Cultivation in Universities Driven by Production-Education Integration. University Chemistry, 2024, 39(10): 289-298. doi: 10.12461/PKU.DXHX202403022

Metrics
  • PDF Downloads(19)
  • Abstract views(2348)
  • HTML views(254)

通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索
Address:Zhongguancun North First Street 2,100190 Beijing, PR China Tel: +86-010-82449177-888
Powered By info@rhhz.net

/

DownLoad:  Full-Size Img  PowerPoint
Return