Ratiometric fluorescence and visual sensing of ATP based on gold nanocluster-encapsulated metal-organic framework with a smartphone

Xiaomeng Zhou Xinjie Wang Li Shang

Citation:  Xiaomeng Zhou, Xinjie Wang, Li Shang. Ratiometric fluorescence and visual sensing of ATP based on gold nanocluster-encapsulated metal-organic framework with a smartphone[J]. Chinese Chemical Letters, 2023, 34(8): 108093. doi: 10.1016/j.cclet.2022.108093 shu

Ratiometric fluorescence and visual sensing of ATP based on gold nanocluster-encapsulated metal-organic framework with a smartphone

English

  • Adenosine 5′-triphosphate (ATP) is not only the primary energy source for cellular processes, but also plays an important role in various biological processes including intracellular energy transfer, signal transduction, DNA replication and membrane transport [14]. The abnormal level of ATP is typically closely associated with many diseases such as hypoglycemia [5], Alzheimer’s disease and malignant tumors [6,7]. Therefore, selective detection and accurate quantification of ATP in biological samples is extremely important. Many approaches have been developed for ATP detection, such as surface plasmon resonance [8,9] chemiluminescence [10], surface enhanced Raman scattering [1113], colorimetric [14,15], and electrochemical approaches [16,17]. However, these methods often need sophisticated operation, require high-cost equipment and time-consuming analysis. Fluorescence assays have received considerable attention in the field of ATP sensing due to their simplicity, rapid response and high sensitivity [1824]. While many fluorescent ATP sensors have been developed in recent years, it still remains challenging to achieve visual and on-site detection of ATP which largely restricts their practical application.

    Paper-based analytical devices have been widely used for molecular analysis, health and environmental monitoring recently due to their low cost, portability and disposability [2527]. For example, Luo et al. [28] synthesized a dual-state emissive chalcone probe with the feature of aggregation-induced emission and loaded the probe into test papers. The obtained fluorescent test papers were successfully employed for human serum albumin test using the whole blood samples. Wang et al. developed a paper-based analytical device with dual-emission carbon dots for the on-site and semiquantitative detection of lead ions in water samples [29]. Importantly, paper-based sensors enable low-cost, sensitive and instant naked eye detection of analytes. Nevertheless, there are few reports about fluorescent paper-based platforms for ATP sensing, which is mainly due to the lack of robust probes.

    Noble metal nanoclusters have recently emerged as promising fluorescent nanoprobes for biosensing and bioimaging duo to their ultrasmall core size (<2 nm), strong photoluminescence, facile availability, and good biocompatibility [30,31]. Metal-organic frameworks (MOFs) have also been explored as excellent sensing materials because of their porous nature, adjustable functionality, and unique optical properties [32,33]. The combination of AuNCs and luminescent MOFs can not only provide multiple emission centers but also endow the MOF/AuNCs assemblies with enhanced selectivity, sensitivity, and stability for fluorescent sensing [26,34]. Herein, we propose a novel paper-based visual and fluorescent ATP sensing platform based on ratiometric luminescent nanoprobes by integrating fluorescent gold nanoclusters (AuNCs) with MOFs. As described in Scheme 1, a ratiometric fluorescent ATP sensor was fabricated by encapsulating blue emissive gold nanoclusters (AuNCs, as the reference signal) into red emissive lanthanide metal-organic frameworks (Eu-MOF, as the response signal), which possess dual emission feature and good stability. Introduction of ATP could trigger the decomposition of AuNCs@Eu-MOF nanocomposites owing to competitive binding of Eu3+ with ATP. Consequently, the red fluorescence of Eu-MOF decreased, while the blue fluorescence of AuNCs is inert to the presence of ATP. Therefore, quantitative fluorescent analysis of ATP can be achieved. Moreover, AuNCs@Eu-MOF probes were loaded into fluorescent test papers, which can be used to detect ATP based on the fluorescence change of the test paper with a smartphone under a UV lamp. Thereby, this study provides a new strategy to enable fluorescent and visual detection of ATP for on-site clinical analysis.

    Scheme 1

    Scheme 1.  Schematic illustration of the fabrication of BSA-AuNCs@Eu-MOF-based ATP nanosensors (A) and further development of paper-based sensors for visual ATP detection (B).

    AuNCs@Eu-MOF composites were prepared through self-assembly using isophthalic acid and Eu3+ as the precursors of MOF in the presence of bovine serum albumin-protected AuNCs (BSA-AuNCs). BSA-AuNCs were first synthesized according to reported strategy [35]. 2-Methylimidazole was then added to trigger the nucleation to construct AuNCs@Eu-MOF at room temperature [36]. As shown in Fig. 1A, AuNCs@Eu-MOF exhibits regular fusiform shape with an approximate length of 5 µm. Compared with pure Eu-MOF with a smooth surface (Fig. S1 in Supporting information), the surface of AuNCs@Eu-MOF was coarse, which is likely due to the attachment of BSA-AuNCs on the MOF surface. Fourier-transform infrared spectroscopy (FTIR, Fig. 1B) further showed that, distinct peaks of BSA-AuNCs at 1656 and 1540 cm−1 corresponding to the characteristic stretching and bending vibrations of amide I, amide II in BSA, respectively, were maintained in the AuNCs@Eu-MOF composites [35]. Moreover, peaks of BSA-AuNCs at 1240 and 1046 cm−1 disappeared after combination with Eu-MOF, which is likely due to the shielding effect of Eu-MOF nanocrystals [37]. XRD analysis further confirmed the crystal structure of AuNCs@Eu-MOF. As shown in Fig. 1C, the negligible effect of AuNCs on structure of Eu-MOF was verified by the similarity of diffraction peaks of AuNCs@Eu-MOF as the pure Eu-MOF. To further confirm the successful assembly of AuNCs and Eu-MOF, thermogravimetric analysis (TGA) was carried out. TGA results showed that AuNCs@Eu-MOF possesses a much higher decomposition temperature than Eu-MOF. The weight loss at 1000 ℃ refers to the Au content in AuNCs@Eu-MOF (Fig. 1D), which is due to the existence of Au element that strengthens the thermal stability of whole framework. All these results confirm that AuNCs were successfully incorporated into Eu-MOF.

    Figure 1

    Figure 1.  (A) SEM image of AuNCs@Eu-MOF; FTIR spectra (B) and XRD patterns (C) of BSA-AuNCs, Eu-MOF and AuNCs@Eu-MOF; (D) TGA curves of Eu-MOF and AuNCs@Eu-MOF.

    We then studied the optical properties of as-prepared AuNCs@Eu-MOF. Before the assembly, BSA-AuNCs exhibit strong blue fluorescence with the emission peak at 446 nm, and Eu-MOF exhibits characteristic red emission of Eu3+ with the emission peak at 616 nm owing to the antenna effect (Figs. 2A and B). As shown in Fig. 2C, the formed AuNCs@Eu-MOF showed emissive features of both BSA-AuNCs and Eu3+. Particularly, the dual emission intensity was strongly dependent on the ratio of AuNCs to Eu3+, and the intensity ratio of Eu-MOF to AuNCs (I616/I446) reached maximum when the ratio of AuNCs to Eu3+ is 40:1. With increasing the concentration of AuNCs in the synthetic procedure, a slight decrease in the emission band of Eu-MOF was observed, which might be due to the coordination of carboxylate groups in BSA-AuNCs with Eu3+ centers. This might induce less energy transfer efficiency from the initial ligand isophthalic acid (ISP) to Eu3+ according to the antenna effect, thus decreasing the Eu3+ characteristic emission [38]. The effect of AuNCs on Eu-MOF emission further confirms the successful assembly of AuNCs and Eu-MOF. We also investigated the fluorescence stability of AuNCs@Eu-MOF in aqueous solution. The fluorescence intensity of AuNCs@Eu-MOF in Tris–HCl (pH 7.4) kept almost unchanged within 24 h, indicating a good stability (Fig. 2D).

    Figure 2

    Figure 2.  Excitation (black) and emission (red) spectra of Eu-MOF (A) and BSA-AuNCs (B) in aqueous solution; (C) fluorescence emission spectra of AuNCs@Eu-MOF with different molar ratios of AuNCs to Eu3+: 80:1 (blue), 40:1 (red), and 20:1 (black); (D) fluorescence stability of AuNCs@Eu-MOF (40:1) versus the time in the aqueous solution. Excitation wavelength: 365 nm.

    Next we evaluated the fluorescence response of AuNCs@Eu-MOF towards ATP. The reaction time was optimized to acquire the best sensing performance as shown in Fig. S2 (Supporting information). With extending the reaction time, the I446/I616 value increased rapidly and reached maximum in 10 min. As expected, red Eu3+ emission gradually decreased while the blue BSA-AuNCs emission remain constant as the concentration of ATP increased (Fig. 3A). A good linear relationship (R2 = 0.998) between the I616/I446 value and ATP concentration in a wide range of 0.01 mmol/L to 2.5 mmol/L was obtained, and as low as 10 µmol/L could be detected (Fig. 3B), which is far below the physiological concentration of ATP (0.4–3.7 mmol/L). The sensitivity of our approach is comparable or even better than many nanomaterial-based fluorescent sensors (Table S2 in Supporting information) [3941]. This suggests that our ratiometric fluorescence sensor could be utilized for ATP detection in real samples [42,43].

    Figure 3

    Figure 3.  (A) Fluorescence emission spectra of AuNCs@Eu-MOF with the addition of increasing concentrations of ATP. Excitation wavelength: 365 nm; (B) changes of the I616/I446 value versus the ATP concentration. Red line denotes the linear fit in the range of 0.01 mmol/L to 2.5 mmol/L; (C) SEM images of AuNCs@Eu-MOF in the presence of ATP; (D) PXRD patterns of AuNCs@Eu-MOF in the absence (black) and presence (red) of ATP.

    It has been previously reported that trivalent lanthanide ions (Ln3+) possess high affinity for oxygen-donor atoms, especially phosphates [44,45]. Therefore, addition of ATP could displace ISP from Eu-MOF, leading to the collapse of the Eu-MOF framework. As a result, energy transfer between ISP and Eu3+ was blocked and the red Eu3+ emission decreased. Meanwhile, the fluorescence of BSA-AuNCs was not affected upon the addition of ATP (Fig. S3 in Supporting information). As a result, the red emission intensity changed significantly after the addition of ATP, which can be used for developing a ratiometric fluorescent ATP sensor with the blue emission of AuNCs as the self-reference. As seen in Fig. 3C, the ATP treatment resulted in partial melting of AuNCs@Eu-MOF due to the degradation of MOF structures. Moreover, the disappearance of XRD peaks of Eu-MOF in the presence of ATP further confirmed the proposed sensing mechanism (Fig. 3D).

    The selectivity of AuNCs@Eu-MOF for ATP towards other potential interferences was investigated. As shown in Fig. S4 (Supporting information), for GTP, UTP and CTP which also have three phosphate groups, a slight increase in the I446/I616 value could also be observed. Since the ATP level in biological fluids is of a greater amount than other triphosphate-containing species, their possible interference on the detection of ATP is negligible [5,46]. Thus this ratiometric fluorescence assay can provide a good selectivity for further ATP sensing in real samples.

    To further facilitate on-site visualization of ATP in practical applications, the above ratiometric fluorescent probes, AuNCs@Eu-MOF, were loaded into paper substrate. As shown in Fig. 4A, when aqueous solution of ATP drops onto the test strips, the color of the paper-based ATP sensor gradually changed from pink to light blue under a UV lamp with an increase of ATP concentration from 0 to 750 µmol/L. To quantitate the ATP concentration using our fluorescent paper sensor, the color information (RGB values) of the paper sensor was read by a smartphone application (Fig. 4B). As shown in Fig. 4C, the ratio of green channel to red channel has a good linear relationship (R2 = 0.986) with the ATP concentration within the range of 25–750 µmol/L. These results suggest that our fluorescent paper sensor can realize portable quantitative detection of ATP simply with a smartphone. Furthermore, human serum (10%) spiked with ATP of different concentrations was used as real samples to validate the practical potential of this fluorescent paper sensor. The recovery rates in human serum calculated by RGB value were found to be 93.5%–120.5% (Table S1 in Supporting information). These results demonstrate that our smartphone-based fluorescent paper sensor has great potential for the visual ATP sensing in biological complex samples.

    Figure 4

    Figure 4.  (A) Schematic diagram for the detection of ATP using a smartphone; (B) the photo of a smartphone installed with a color recognition App; (C) color change of test stripes (green channel/red channel) versus the concentration of ATP (the insets show photos that were taken with a smartphone under a 310 nm UV lamp).

    In summary, we have developed a novel ratiometric fluorescence assay for the detection of ATP based on ATP-triggered decomposition of AuNCs@Eu-MOF. The presence of ATP could displace ISP from Eu-MOF, leading to the collapse of the Eu-MOF framework. As a result, the red Eu3+ emission decreased gradually while the blue BSA-AuNCs emission remains constant. Consequently, a ratiometric fluorescent sensor for ATP can be established, which showed competitive sensitivity and selectivity towards ATP sensing. Moreover, a fluorescent paper-based sensor was fabricated with these novel probes to render a simple, visual assay of ATP in human serum, and satisfactory results were obtained. We envision that the present visual sensing strategy could provide useful guidelines for further developing novel optical biosensors.

    The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

    This work is supported by the National Natural Science Foundation of China (No. 22274131) and the Research Fund of the State Key Laboratory of Solidification Processing (NPU), China (No. 2020-QZ-01).

    Supplementary material associated with this article can be found, in the online version, at doi:10.1016/j.cclet.2022.108093.


    1. [1]

      Z. Gao, Z. Qiu, M. Lu, J. Shu, D. Tang, Biosens. Bioelectron. 89 (2017) 1006–1012. doi: 10.1016/j.bios.2016.10.043

    2. [2]

      X. Shen, G. Mizuguchi, A. Hamiche, C. Wu, Nature 406 (2000) 541–544. doi: 10.1038/35020123

    3. [3]

      P.B. Dennis, A. Jaeschke, M. Saitoh, et al., Science 294 (2001) 1102–1105. doi: 10.1126/science.1063518

    4. [4]

      M. Mei, L. Mu, Y. Wang, et al., Anal. Chem. 94 (2022) 11813–11820. doi: 10.1021/acs.analchem.2c02030

    5. [5]

      P.K. Yeung, S.S. Kolathuru, S. Mohammadizadeh, F. Akhoundi, B. Linderfield, Metabolites 8 (2018) 30–43. doi: 10.3390/metabo8020030

    6. [6]

      S.L. Cai, Y.B. Zheng, S.H. Cao, X.H. Cai, Y.Q. Li, Chem. Commun. 52 (2016) 12450–12453. doi: 10.1039/C6CC04899D

    7. [7]

      J.K. Ahn, H.Y. Kim, K.S. Park, H.G. Park, Anal. Chem. 90 (2018) 11340–11343. doi: 10.1021/acs.analchem.8b02014

    8. [8]

      J.H. Park, J.Y. Byun, W.B. Shim, S.U. Kim, M.G. Kim, Biosens. Bioelectron. 73 (2015) 26–31. doi: 10.3348/jksr.2015.73.1.26

    9. [9]

      L. Xie, X. Yan, Y. Du, Biosens. Bioelectron. 53 (2014) 58–64. doi: 10.1016/j.bios.2013.09.031

    10. [10]

      Y.P. Dong, Y. Zhou, J. Wang, J.J. Zhu, Anal. Chem. 88 (2016) 5469–5475. doi: 10.1021/acs.analchem.6b00921

    11. [11]

      H. Shi, N. Chen, Y. Su, H. Wang, Y. He, Anal. Chem. 89 (2017) 10279–10285. doi: 10.1021/acs.analchem.7b01881

    12. [12]

      X. Zhang, Y. Ge, M. Liu, et al., Anal. Chem. 94 (2022) 7823–7832. doi: 10.1021/acs.analchem.1c05649

    13. [13]

      C. Wu, S. Wang, X. Luo, R. Yuan, X. Yang, Chem. Commun. 56 (2020) 1413–1416. doi: 10.1039/c9cc08440a

    14. [14]

      D. Cheng, Y. Li, J. Wang, et al., Chem. Commun. 51 (2015) 8544–8546. doi: 10.1039/C5CC01713K

    15. [15]

      S. Li, X. Zhao, X. Yu, et al., Anal. Chem. 91 (2019) 14737–14742. doi: 10.1021/acs.analchem.9b04116

    16. [16]

      G. Wang, Q. Xu, L. Liu, et al., ACS Appl. Mater. Interfaces 9 (2017) 31153–31160. doi: 10.1021/acsami.7b09529

    17. [17]

      J. Zheng, X. Li, K. Wang, J. Song, H. Qi, Anal. Chem. 92 (2020) 10940–10945. doi: 10.1021/acs.analchem.0c00569

    18. [18]

      C. Qin, Y. Li, Q. Li, C. Yan, L. Cao, Chin. Chem. Lett. 32 (2021) 3531–3534. doi: 10.1016/j.cclet.2021.05.006

    19. [19]

      Z. Wu, M. Liu, Z. Liu, Y. Tian, J. Am. Chem. Soc. 142 (2020) 7532–7541. doi: 10.1021/jacs.0c00771

    20. [20]

      X. Zhou, L. Shang, Curr. Anal. Chem. 17 (2021) 1–12. doi: 10.2174/1573411017666210909121746

    21. [21]

      Y. Zhong, T. Yi, J. Mater. Chem. B 7 (2019) 2549–2556. doi: 10.1039/c9tb00191c

    22. [22]

      K. Fan, S.S. Bao, W.X. Nie, C.H. Liao, L.M. Zheng, Inorg. Chem. 57 (2018) 1079–1089. doi: 10.1021/acs.inorgchem.7b02513

    23. [23]

      Y. Wu, J. Wen, H. Li, S. Sun, Y. Xu, Chin. Chem. Lett. 28 (2017) 1916–1924. doi: 10.1016/j.cclet.2017.09.032

    24. [24]

      X. Shi, H. Xu, Y. Wu, et al., J. Anal. Test. 5 (2021) 165–173. doi: 10.1007/s41664-021-00172-1

    25. [25]

      X. Lyu, V. Hamedpour, Y. Sasaki, Z. Zhang, T. Minami, Anal. Chem. 93 (2021) 1179–1184. doi: 10.1021/acs.analchem.0c04291

    26. [26]

      Q. Gao, S. Xu, C. Guo, Y. Chen, L. Wang, ACS Appl. Mater. Interfaces 10 (2018) 16059–16065. doi: 10.1021/acsami.8b04531

    27. [27]

      W. Li, X. Zhang, S. Chen, Y. Ji, R. Li, Chin. Chem. Lett. 33 (2022) 4405–4410. doi: 10.1016/j.cclet.2021.12.026

    28. [28]

      Z. Luo, T. Lv, K. Zhu, et al., Angew. Chem. Int. Ed. 59 (2020) 3131–3136. doi: 10.1002/anie.201915046

    29. [29]

      H. Wang, L. Yang, S. Chu, et al., Anal. Chem. 91 (2019) 9292–9299. doi: 10.1021/acs.analchem.9b02297

    30. [30]

      Z.J. Wang, Q. Li, L.L. Tan, C.G. Liu, L. Shang, J. Anal. Test. 6 (2022) 163–177. doi: 10.1007/s41664-022-00224-0

    31. [31]

      J. Xu, J. Li, W. Zhong, et al., Chin. Chem. Lett. 32 (2021) 2390–2394. doi: 10.1016/j.cclet.2021.02.037

    32. [32]

      X. Zhou, J. Li, L.L. Tan, Q. Li, L. Shang, J. Mater. Chem. B 8 (2020) 3661–3666. doi: 10.1039/c9tb02319d

    33. [33]

      S. Wu, H. Min, W. Shi, P. Cheng, Adv. Mater. 32 (2020) e1805871. doi: 10.1002/adma.201805871

    34. [34]

      X. Yin, B. Yang, B. Chen, M. He, B. Hu, Anal. Chem. 91 (2019) 10596–10603. doi: 10.1021/acs.analchem.9b01721

    35. [35]

      X.Le Guével, B. Hötzer, G. Jung, et al., J. Phys. Chem. C 115 (2011) 10955–10963. doi: 10.1021/jp111820b

    36. [36]

      C. Guo, Y. Zhang, Y. Guo, et al., Chem. Commun. 54 (2018) 252–255. doi: 10.1039/C7CC07698C

    37. [37]

      Z. Wu, H. Yang, S. Pan, H. Liu, X. Hu, ACS Sens. 5 (2020) 2211–2220. doi: 10.1021/acssensors.0c00853

    38. [38]

      Z.R. Yang, M.M. Wang, X.S. Wang, X.B. Yin, Anal. Chem. 89 (2017) 1930–1936. doi: 10.1021/acs.analchem.6b04421

    39. [39]

      X. Zheng, R. Peng, X. Jiang, et al., Anal. Chem. 89 (2017) 10941–10947. doi: 10.1021/acs.analchem.7b02763

    40. [40]

      K. Wang, M. Qian, H. Qi, Q. Gao, C. Zhang, Nanoscale 12 (2020) 15663–15669. doi: 10.1039/d0nr02149k

    41. [41]

      W. Qiang, H. Hu, L. Sun, H. Li, D. Xu, Anal. Chem. 87 (2015) 12190–12196. doi: 10.1021/acs.analchem.5b03075

    42. [42]

      M. Liu, X. Ren, X. Liu, et al., Chin. Chem. Lett. 31 (2020) 3117–3120. doi: 10.1016/j.cclet.2020.06.024

    43. [43]

      R. Mo, T. Jiang, R. DiSanto, W. Tai, Z. Gu, Nat. Commun. 5 (2014) 3364–3373. doi: 10.1038/ncomms4364

    44. [44]

      H. He, C. Li, Y. Tian, P. Wu, X. Hou, Anal. Chem. 88 (2016) 5892–5897. doi: 10.1021/acs.analchem.6b00780

    45. [45]

      S.M. Harris, J.T. Nguyen, S.L. Pailloux, et al., Environ. Sci. Technol. 51 (2017) 4549–4558. doi: 10.1021/acs.est.6b05815

    46. [46]

      V. Vultaggio-Poma, A.C. Sarti, F. Di Virgilio, Cells 9 (2020) 2496–2517. doi: 10.3390/cells9112496

  • Scheme 1  Schematic illustration of the fabrication of BSA-AuNCs@Eu-MOF-based ATP nanosensors (A) and further development of paper-based sensors for visual ATP detection (B).

    Figure 1  (A) SEM image of AuNCs@Eu-MOF; FTIR spectra (B) and XRD patterns (C) of BSA-AuNCs, Eu-MOF and AuNCs@Eu-MOF; (D) TGA curves of Eu-MOF and AuNCs@Eu-MOF.

    Figure 2  Excitation (black) and emission (red) spectra of Eu-MOF (A) and BSA-AuNCs (B) in aqueous solution; (C) fluorescence emission spectra of AuNCs@Eu-MOF with different molar ratios of AuNCs to Eu3+: 80:1 (blue), 40:1 (red), and 20:1 (black); (D) fluorescence stability of AuNCs@Eu-MOF (40:1) versus the time in the aqueous solution. Excitation wavelength: 365 nm.

    Figure 3  (A) Fluorescence emission spectra of AuNCs@Eu-MOF with the addition of increasing concentrations of ATP. Excitation wavelength: 365 nm; (B) changes of the I616/I446 value versus the ATP concentration. Red line denotes the linear fit in the range of 0.01 mmol/L to 2.5 mmol/L; (C) SEM images of AuNCs@Eu-MOF in the presence of ATP; (D) PXRD patterns of AuNCs@Eu-MOF in the absence (black) and presence (red) of ATP.

    Figure 4  (A) Schematic diagram for the detection of ATP using a smartphone; (B) the photo of a smartphone installed with a color recognition App; (C) color change of test stripes (green channel/red channel) versus the concentration of ATP (the insets show photos that were taken with a smartphone under a 310 nm UV lamp).

  • 加载中
计量
  • PDF下载量:  2
  • 文章访问数:  310
  • HTML全文浏览量:  16
文章相关
  • 发布日期:  2023-08-15
  • 收稿日期:  2022-09-14
  • 接受日期:  2022-12-21
  • 修回日期:  2022-12-16
  • 网络出版日期:  2022-12-24
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

/

返回文章